<?xml version="1.0" standalone="yes"?>
<?xml-stylesheet type="text/xsl" href="..\..\XSLTemplates\ErrorsStyleSheet.xsl"?>
<Error>
<ErrorNumber>15534</ErrorNumber>
<ErrorFamily>Autoloader</ErrorFamily>
<ErrorMessage>
ALE: %s %d timed out while moving
</ErrorMessage>
<AppliesTo>
<UnnumberedList>
<ListItem><Text>Trendsetter_VLF</Text></ListItem>
<ListItem><Text>Platesetter_VLF</Text></ListItem>
</UnnumberedList>
</AppliesTo>
<ServiceInformation>
<DescriptionText><text>
Check for a low value of the NVS parameter "move_timeout" by typing
"set altim move" in the diagnostic monitor. This value is the maximum time
allowed by the firmware for moving a stepper axis. Verify the mechanics
for anything that could prevent the axis from moving at a normal pace.
</text></DescriptionText>
</ServiceInformation>
<OperatorAction>
<DescriptionText><text>
This is not an operator serviceable error.  Press resume or reset the
machine to continue production.  Call CreoScitex response center.
</text></DescriptionText>
</OperatorAction>
<Cause>
An axis is taking too much time to move to the desired position.
</Cause>
<SeeAlso>
<UnnumberedList>
</UnnumberedList>
</SeeAlso>
<OtherLinks>
<Link><LinkAddress>..\..\ShowAllErrors.htm</LinkAddress><LinkTitle>Firmware 0 Error Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllCommands.htm</LinkAddress><LinkTitle>Firmware 0 Command Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllNVS.htm</LinkAddress><LinkTitle>Firmware 0 NVS Index</LinkTitle></Link>
</OtherLinks>
<Updated>
Updated: Wed Jul 16 19:33:10 2008 PST
</Updated>
<Links>
<Link><LinkAddress>http://techplanet.creo.com/output/computer_to_plate/vlf_platesetter/content/troubleshooting/15534.htm</LinkAddress><LinkTitle>Other: Troubleshooting information</LinkTitle></Link>
</Links>
</Error>